Fuel loss
The prime mover spends extra power overcoming the counter-field. That extra power comes straight out of the fuel tank.
Recovering lost energy. Same fuel, more usable power.
Once a generator is under load, its own counter-field and reactive current act as a hidden brake on the prime mover. NEO GENPOWER targets that loss and raises efficiency without replacing your generator.

What inflates your fuel bill is the resistance your own output creates. It shows up in three places.
The prime mover spends extra power overcoming the counter-field. That extra power comes straight out of the fuel tank.
Under load, a braking effect forms on the rotor. The engine works harder than it needs to, and bearings and couplings wear faster.
Reactive current produces heat in the windings and frame that does no useful work. More heat means faster insulation ageing and higher failure risk.
Power generation always creates a counter-field that brakes the rotor. The trouble is the share of that field and of the reactive current that never becomes useful work and returns to the system as load.

NEO GENPOWER is a module developed by NEO R&D that limits back-EMF at its source and absorbs reactive energy, converting it into active power.

Blocks the braking effect created by Lenz’s law at its source, or diverts it to a separate line.

Absorbs reactive current and reactive energy in the circuit and turns it into usable active power.
The gain depends on load and operating conditions. Every point of efficiency gained directly cuts the fuel burned for the same electrical output.
Saves 16,700 L on a 100,000 L/year consumption.
Saves 25,900 L on a 100,000 L/year consumption.
Saves 33,300 L on a 100,000 L/year consumption.
CO₂ and exhaust emissions fall in exact proportion to the fuel saved.
Formula: fuel saving (%) = 1 − 1 / (1 + efficiency gain). Results are reported for every installation from comparative on-site measurements with the module switched in and out, never from estimates.
For guidance only. Firm figures are reported after a 24-hour baseline and a comparison measurement on site. CO₂ uses a diesel emission factor of 2.68 kg CO₂/L.

Suitable for generators from 1 kW to 5 MW. The longer and harder your generator runs, the more GENPOWER returns.
No new generator is needed. The module integrates into the existing system.
Diesel engines, turbines and renewable hybrids such as wind, hydro and biogas.
Our engineers analyse and design each unit around your kVA rating and load profile.
Generator type, kVA rating and load profile are mapped.
At least 24 hours of active power, fuel and thermal logging with NEO switched out.
Bypass-equipped module fitted without altering the existing system.
Performance, power quality and fuel logged under the same load with NEO switched in.
Efficiency, fuel in L/h and temperature differences are reported.
Electrical safety, stability and thermal risks are closed out one by one in the commissioning report.
The energy is being lost anyway. The only choice is to keep paying for it or to win it back.