Industry 5.0 power quality

NEOKOM

Next-generation power quality and compensation panel

A single-enclosure, remotely monitored and autonomous answer to reactive penalties, harmonic pollution and nuisance RCD trips. No more separate panels, messy wiring or multiple installation crews.

cos φ ≥ 0.98Target power factor
3rd–25thHarmonics actively filtered
24 monthsNEO MAKİNA warranty
NEOKOM power quality and compensation panel
Plug & playfactory-tested delivery
What happens on site

Four threats every site faces

Each one is an operating cost on its own. Together they multiply both the bills and the failures.

Reactive penalties

Sites that fall outside EPDK limits face penalty charges month after month, driving up operating costs.

Harmonic pollution

Rectifier and inverter loads push IEEE 519 and TS EN 50160 limits and damage sensitive equipment.

Nuisance RCD trips

High-frequency capacitive leakage trips standard Type AC relays for no reason, leaving the site running blind.

Call-out costs

At unmanned sites, even a minor fault means a technician call-out and a long outage.

Solution architecture

Four function blocks, one enclosure, one point of contact

NEOKOM brings compensation, filtering, protection and monitoring together in one compact Industry 5.0 panel.

  • 1 · Automatic compensation: hybrid SVG plus 7% detuned capacitor steps, with independent per-phase reactive injection.
  • 2 · Harmonic + EMI filter: active filtering of the 3rd to 25th harmonics and a two-stage EMI/RFI line filter.
  • 3 · Protection + automation: tested auto-recloser, AAC, PCB and SPD protection.
  • 4 · Monitoring and control: Modbus RTU/TCP with optional 4G for round-the-clock visibility.
Layered function blocks inside the NEOKOM panel
Clean power

Precision that removes penalty risk

Stay safely inside EPDK limits at all times. Fast load changes that conventional systems cannot follow are handled autonomously.

Distorted waveform leaving the NEOKOM filter module as a clean sine wave

Precise tracking

SVG and stepped capacitors lock the power factor at the target of cos φ ≥ 0.98.

Active filtering

Pollution from the 3rd to the 25th harmonic is cleaned up (≤ 30 A rms), targeting THD-I ≤ 8% on the supply current.

High-frequency barrier

A two-stage EMI/RFI line filter (≥ 40 dB) protects sensitive electronics.

24/7 visibility

Fix faults without a site visit

NEOKOM keeps manual intervention to a minimum and aims to eliminate technician call-out costs.

  • Tested auto-recloser: brings the system back within 5–10 seconds after a transient fault. A technician is only needed for a permanent fault.
  • Modbus RTU/TCP and 4G: streams every power parameter and fault state to your central SCADA or the cloud in real time.
  • Layered protection: AAC, O/V–U/V True-RMS protection and SPD T1+T2+T3 (12.5 kA) against lightning and overvoltage.
  • Full event log: the PRO version stores the last 500 faults and events.
NEOKOM remote monitoring dashboard on a tablet
Product family

Choose the NEOKOM build that fits your site

FeatureNEOKOM STANDARTNEOKOM PRO
Automatic reactive compensation (cos φ ≥ 0.98)IncludedIncluded
Active + EMI/RFI harmonic filterIncludedIncluded
Nuisance RCD trip prevention (Type A-SI / B)IncludedIncluded
O/V–U/V True-RMS protectionOptionIncluded
Phase loss / reversal / imbalance protectionNot includedIncluded
Auto-recloserManualAutomatic (5–10 s)
SPD T1+T2+T3 and PCB protectionSpace providedIncluded
Event log and remote monitoringBasic — RTUFull — RTU/TCP, 500 events
Best forEasy-access sites with regular maintenanceUnmanned, remote sites where downtime is costly

Upgrade path: a STANDARD unit can be upgraded to PRO on site with an upgrade kit.

Applications

Wherever power quality matters

Telecom base station on a mountain

Telecom & base stations

Autorecloser and remote monitoring keep unmanned mountain and rural sites on air.

Data centre server aisle

Critical LV & data centres

Built-in PCB and an advanced SPD layer give sensitive IT loads the highest level of protection.

Factory floor with motors and drive panels

Factories & process panels

Full isolation of the heavy harmonic pollution and EMI created by rectifiers, inverters and motor drives.

Power plants — auxiliary LV switchboards Rectifier- and inverter-heavy processes
Technical data

International compliance and design criteria

Ratings
Supply3F+N+PE, 400/230 V AC, 50 Hz
Site installed load≤ 30 kVA
Reactive power≤ 15 kVAr (bidirectional)
Rated current≤ 63 A / phase
Harmonic current≤ 30 A rms, 3rd–25th harmonic
WithstandIcw 6 kA (panel), IP55 optional
Standards
IEC 61439Low-voltage switchgear assemblies
IEEE 519Harmonic limits
TS EN 50160Supply voltage characteristics
IEC 61008 / 61009Residual current devices
TS EN 62305Lightning and overvoltage protection

Every NEOKOM panel passes a full performance test in the factory before it ships.

The NEOKOM value equation

The shortest, safest route to uninterrupted operation

Zero penalty risk

Reactive values stay inside EPDK limits at all times.

Maximum OPEX savings

No more unnecessary call-outs or fault-finding costs.

Effortless upgrades

Move from STANDARD to PRO on site by adding modules.

  1. Transparent budgeting

    Lump-sum pricing per site, with tiered discounts for volume orders.

  2. Plug-and-play delivery

    Delivered fully assembled and factory-tested to IEC 61439 and IEEE 519. Your team only connects the cables.

  3. Full cover

    24-month NEO MAKİNA warranty from the day of commissioning.

Site-specific analysis

Make your sites smarter. Cut your OPEX.

Summarise your project and our engineering team will come back with a site-specific solution within 24 hours.

Send us: site type and count, installed load (kVA), your last three electricity bills (including reactive charges) and any power analyser readings.
Phone & WhatsApp+90 532 289 43 31
Head Office — İzmirAdalet Mah. Manas Blv. No:47 B İç Kapı No:3509, Bayraklı / İZMİR
R&D and Innovation Centre — AnkaraSelçuklu Caddesi No: 135 Alt, Ankara
London & Cairo Offices55 Stoke Newington High Street N16 8EL London, UKAhmet Kasim Gouda Str. 41/1 Nasr City, Cairo, Egypt